Drainage Strategy for a care home in London

Case study

A drainage strategy for a care home in London, prepared for planning and approved.

The constraint

The first question on any site is whether the ground will take water, because that decides whether the scheme is a soakaway or attenuation with a restricted discharge.

What we did

The scheme uses raingardens and a detention basin.

The numbers

Discharge rate0.6l/s
Climate change allowance, 1 in 30 year35%
Climate change allowance, 1 in 100 year40%
Management catchmentLondon
Site classificationGreenfield
Onn Point proposed drainage strategy for a care home in London
The drainage strategy for this scheme, as it went to planning. Client name and address removed.

Every SuDS option, and why

Each option in the SuDS hierarchy was considered for this site. This is the assessment as it went into the report:

OptionUsedWhy
Rainwater HarvestingNoThe use of rainwater harvesting has not been proposed for this site as it is not considered the most effective method of capturing water at source for the proposed development.
Green RoofsNoGreen roofs have not been proposed for this site as they are not considered the most effective or economical way of capturing water at source for the proposed development.
Infiltration SystemsNoSystems such as soakaways are not considered viable for this site due to underlaying ground conditions.
Proprietary Treatment SystemsNoThe use of proprietary treatment systems is not considered economically viable or deemed required on this site.
Filter StripsNoFilter strips have not been considered the most effective proposal for this site due to the proposed site layout.
Filter DrainsNoFilter Drains have not been considered the most effective proposal for this site due to the proposed site layout.
SwalesNoSwales are not suitable for this scheme due to available space and proposed land use.
Bioretention SystemsYesBioretention Systems in the form of a rain garden have been incorporated into the proposed drainage strategy.
Porous PavementsNoThe use of porous paving is not considered suitable or viable for the proposed development. The attenuation tank will reduce the quantity of rainfall runoff reaching the sewer/watercourse. Cellular Attenuation Tank is.

The kind of condition this discharges

Wording differs between officers, but a scheme like this one is normally answering a condition along these lines:

No development shall commence until a detailed surface water drainage scheme, demonstrating that surface water will be restricted to greenfield run-off rates for all storm events up to and including the 1 in 100 year event plus an allowance for climate change, has been submitted to and approved in writing by the Local Planning Authority.

The greenfield run-off calculation and the attenuation volume are what answer this one. There is a fuller guide to discharging drainage planning conditions if you want to read up on the process.

Outcome

Hydraulic simulation showed no flooding in the 1-, 30- or 100-year storm events, including the climate change allowance. The scheme was approved at planning.

Every scheme in these case studies was approved — that is the point of the exercise. If you have a drainage condition to discharge, send us the wording and the site address and we will tell you exactly what is needed.

More on drainage design in London, browse the rest of our case studies, or see what a drainage strategy involves.